Specs at a glance
-
Measuring range
More than 60 measuring components available (depending on concentration and sample gas composition)
Up to 6 components simultanously
2 measuring ranges per component
Automatic measuring range switching (adjaustable)
2 limit values per component
Measuring ranges depend on application and combination of measuring components
Field of application
The MCS300P is an extractive process photometer for measuring gaseous or liquid media. It measures IR- and VIS-active components with variable measuring ranges from very low (ppm) to high (vol%) concentrations. For monitoring toxic or flammable mixtures, it features special process cells with integrated protective devices, such as double seals and purge gas chambers on both sides.
Process monitoring in production of vinyl chloride or isocyanate
Process control in the chemical industry
Process monitoring in the production of plastics
Monitoring of exhaust gas purification plants
Device properties:
Simultaneous measurement of up to 6 components
Process cells up to 60 bar and 200 °C available
Automated sample point switching
Protective devices for measurement of toxic or flammable mixtures
Extended operation via PC and SOPAS ET software
Flexible I/O module system
Benefits
Automatic adjustment without expensive test gases
Integration into existing networks
Integration of external parameters like temperature or pressure
Suitable for explosive environments
Easy installation and maintenance thanks to transparent, compact design
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Interference filter correlation, Gas filter correlation
-
Measured variables
Br2, CCl4, C2Cl4, CCl2F2, C3F6, CH4, C2H2, C2H4, C2H6, C3H4, C3H6, C3H8, C4H6, C4H8, C4H10, C6H6, C6H14, C7H8, CH3Cl, CH2Cl2, CHCl3, C2H3Cl, C2H2Cl2, C2H4Cl2, C2HCl3, C6H5Cl, C6H4Cl2, CHCl2F, CH3OH, C3H7OH, C2H4(OH)2, CH3CHO, HCOOH, CH3COOC2H3, C2H2O, Cl2, CO, CO2, COCl2, HCl, HCN, HF, H2O, NH3, NO, N2O, NO2, R-NCO, SO2, SiF4, many other IR / VIS active gases and liquids
-
Measuring range
More than 60 measuring components available (depending on concentration and sample gas composition)
Up to 6 components simultanously
2 measuring ranges per component
Automatic measuring range switching (adjaustable)
2 limit values per component
Measuring ranges depend on application and combination of measuring components -
Ambient temperature range
+5 °C ... +40 °C
Temperature change maximum ±10 °C/h -
Ambient humidity
≤ 80 %
Non-condensing -
Hazardous area approvals
IECEx:
Ex pxb IIC T3...T4 Gb
Ex pzc IIC T3...T4 Gc
Process cuvette: Ex eb IIC Gb
ATEX:
II 2G Ex pxb IIC T4 Gb
II 2G Ex pxb IIC T3 Gb
Process cuvette: II 2G Ex e IIC Gb
II 3G Ex pzc IIC T4 Gc
II 3G Ex pzc IIC T3 Gc -
Degree of protection
IP65: measuring cuvette depending on version
-
Product safety
CE
-
-
Technical Information (TI)
Opto Box
-
Technical Information (TI)
English version - 01/2025New version available in EnglishThe Opto-Box is part of the modular MODIOS I/O system and
is installed in an existing I/O module box system.EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
979.6 KB
File name:
8031175_AE00_TI_OptoBox_en_V2-2_2012-08_EHS.pdf
-
-
-
Technical Information (TI)
I/O Module Box
-
Technical Information (TI)
English version - 01/2025New version available in Englishavailable for MCS300P or MCS300P Ex
EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
947.3 KB
File name:
8031177_AE00_TI_IO-Modulebox_en_V1-1_2012-08_EHS.pdf
-
-
-
Technical Information (TI)
MCS300P Technical Information
-
Technical Information (TI)
English version - 08/2025New version available in EnglishMulticomponent Analyzer System
(This document is only valid in combination with the
"Operating Instructions MCS300P" or
"Operating Instructions MCS300P-Ex".)EN 01/08/2025Language:
English
Version:
01/08/2025
File size:
1.5 MB
File name:
8031256_AE00_TI_MCS300P_en_V1-2_2025-08_EHS.pdf
-
-
-
Technical Information (TI)
HCX8 Heat Control
-
Technical Information (TI)
English version - 01/2025New version available in EnglishThe HC8X is an 8-channel heat control. It serves to regulate single
and multi-phase heating circuits.EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
1.5 MB
File name:
8031183_AE00_TI_HC8X_en_V1-1_2013-01_EHS.pdf
-
-
-
Operating Instruction (BA)
SFU
-
Operating Instruction (BA)
English version - 01/2025New version available in EnglishGas Sampling Unit
EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
2.6 MB
File name:
8029819_YJ80_OI_SFU_IP23_en_V3-0_2015-08_EHS.pdf
-
-
-
Operating Instruction (BA)
SFU weatherproof enclosure
-
Operating Instruction (BA)
English version - 01/2025New version available in EnglishGas Sampling Unit with Weatherproof Enclosure
EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
2.6 MB
File name:
8029817_14SF_OI_SFU_IP54_en_V1-1_2019-07_EHS.pdf
-
-
-
Operating Instruction (BA)
MCS300P Ex
-
Operating Instruction (BA)
English version - 01/2025New version available in EnglishMulti-Component Analysis System
EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
4.3 MB
File name:
8029886_AE00_OI_MCS300P_Ex_en_V1-9_2025-03_EHS.pdf
-
-
-
Operating Instruction (BA)
AGK Gas Cell
-
Operating Instruction (BA)
English version - 09/2025New version available in EnglishThe cell is part of a measuring system for analyzing gas mixtures and
is used exclusively for the spectrometric analysis of gases under
process conditions.EN 01/09/2025Language:
English
Version:
01/09/2025
File size:
1.5 MB
File name:
8030439_AE00_OI_AGK_en_V2-0_2025-09_EHS.pdf
-
-
-
Operating Instruction (BA)
FGK - High-Pressure Gas and Liquid Cell
-
Operating Instruction (BA)
English version - 01/2025New version available in EnglishThe FGK cell is part of a measuring system suitable for
analyzing gases and liquids.EN 01/01/2025Language:
English
Version:
01/01/2025
File size:
1.8 MB
File name:
8030448_AE00_OI_FGK_en_V3-0_2012-07_EHS.pdf
-
-
-
Operating Instruction (BA)
PGK
-
Operating Instruction (BA)
English version - 04/2025New version available in EnglishGas Cell
EN 01/04/2025Language:
English
Version:
01/04/2025
File size:
959 KB
File name:
8030445_AE00_OI_PGK_en_V2-2_2025-04_EHS.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons