                  Specs at a glance
- 
                              Input2 x universal (current, voltage, R, RTD, TC, resistance) 
- 
                              Output2 x Analog (current, voltage) 
- 
                              DisplayLCD 
 7 segment
 Multicolour
 Bargraph
 TAG unit
 Colour change in case of failure
- 
                              Power SupplyWide range power supply 24 to 230 V AC/DC (-20 % / +10 %) 50/60 Hz 
Field of application
Analog measured values are indicated, evaluated and calculated by the process transmitter. With the integrated loop power supply two-wire sensors can be powered. The universal inputs enable the connection of current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. Via analog outputs process signals can be forwarded. The integrated application package "differential pressure" allows the quick and easy commissioning for differential pressure applications.
The RMA42 process transmitter exhibits a display, analog inputs for process and status signals, analog and digital outputs, and an interface for configuration. Connected sensors can be powered by the integrated LPS. All measured and calculated values are available as a signal source for display, outputs, relays and the interface.
- Plant and apparatus engineering 
- Control rooms and cabinets 
- Process control, recording and supervision 
- Signal adjustment and conversion 
- Overfill protection (WHG) 
Benefits
- SIL 2 approval (optional); - Marine approval 
- 1 or 2 calculated values and linearization table 
- Min./max. value saved 
- 5-digit 7-segment LC display, backlit 
- 1 or 2 universal inputs 
- 2 relays (optional) 
- Digital status output (Open Collector) 
Videos
Lean selection
- 
        Standard products 
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
 
                              - 
        Standard products 
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
- 
        Specialized products 
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity | 
|---|---|---|
| 
 Fundamental selection Meet your basic measurement needs | Technical excellence | Simplicity | 
| 
 Lean selection Handle your core processes easily | Technical excellence | Simplicity | 
| 
 Extended selection Optimize your processes with innovative technologies | Technical excellence | Simplicity | 
| 
 Xpert selection Master your most challenging applications | Technical excellence | Simplicity Variable | 
Predecessor
- 
                        
                                      - 
                                                    Technical Information (TI)
 TI RMA42English version - 01/2025 Process transmitter with control unit EN 13/01/202504/03/202231/07/201910/03/201602/11/2015Language: English Version: 13/01/2025 File size: 1 MB File name: TI00150REN_0825-00.pdf 
- 
                                                    
- 
                        - 
                                                            Technical Information (TI)
 TI RMA42Process transmitter with control unit EN 13/01/202504/03/202231/07/201910/03/201602/11/2015Language: English Version: 13/01/2025 File size: 1 MB File name: TI00150REN_0825-00.pdf 
- 
                                                            
- 
                        - 
                                                            Operating Instruction (BA)
 BA RMA42Process transmitter with control unit EN 13/01/202504/03/202231/07/201910/03/201602/11/2015Language: English Version: 13/01/2025 File size: 1.8 MB File name: BA00287REN_0825-00.pdf 
- 
                                                            
- 
                        - 
                                                            Short Instruction (KA)
 KA RMA42Process transmitter with control unit EN 13/01/202504/03/202231/07/201924/06/201627/03/2015Language: English Version: 13/01/2025 File size: 1.2 MB File name: KA00286REN_1925-00.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 RMA42X-HAEinbauanleitung für den Austausch des Display des RMA42 EN 30/01/2025Language: English Version: 30/01/2025 File size: 250 KB File name: 71098916.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 RMA42X-NxEinbauanleitung für den Austausch des Powerbaord des RMA42 EN 30/01/2025Language: English Version: 30/01/2025 File size: 1.6 MB File name: 71098919.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 RMA42X-NxEinbauanleitung für den Austausch des Mainboard RMA42 EN 30/01/2025Language: English Version: 30/01/2025 File size: 1.6 MB File name: 71098917.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 RMA42T-Einbauanleitung für den Austausch des CPU Karte inkl. Display RAM42 EN 30/01/2025Language: English Version: 30/01/2025 File size: 1.6 MB File name: 71098914.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 RMA42X-DAEinbauanleitung für den Austausch des Display des RMA42 EN 30/01/2025Language: English Version: 30/01/2025 File size: 259.3 KB File name: 71098915.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 RMA42X-NxEinbauanleitung für den Austausch des Mainbaord des RMA42 EN 30/01/2025Language: English Version: 30/01/2025 File size: 1.6 MB File name: 71098917.pdf 
- 
                                                            
- 
                        - 
                                                            Installation Instructions (EA)
 RMA42X-NxEinbauanleitung für den Austausch des Powerboard RMA42 EN 30/01/2025Language: English Version: 30/01/2025 File size: 1.6 MB File name: 71098919.pdf 
- 
                                                            
 
                                             
                                    .jpg) 
                                     
                                     
                                   
                                   
                                   
                                   
                                   
                                  